USG shaft wall systems are non-loadbearing gypsum wall partition assemblies constructed from outside the shaft at each floor. Shafts are enclosed early in construction, and the walls are finished later, along with interior partitions. Installation is quick and easy, using components and application procedures familiar to drywall contractors.
Learn MoreUSG Head of Shaft Wall Details CAD - J2131. More; Need Help? Contact Us Samples Inquiries Media Inquiries Retiree Inquiries Customer Service (Sales) 1-800-950-3839
Learn MoreUSG Corporation. 550 West Adams Street, Chicago, IL 60661. T. 800-USG4YOU www.USG.com. HEAD OF SHAFT WALL DETAILS - USG J2131 R1.
Learn MoreOur Shaftwall Metal Framing can be installed for vertical and horizontal encasement applications. With the help of a variety of mold, moisture, and fire-resistant gypsum and cement boards that USG Middle East offers, the result will be thinner and lighter walls that can withstand high lateral loads and improve acoustic performance. 4 Items
Learn MoreUSG SHEETROCK ©BRAND SHAFT LINER GYPSUM PANELS, CUT TOP OF PANEL 1" LESS THAN FLOOR TO CEILING HEIGHT, TYPICAL Scale: 3" = 1' - 0" HEAD OF WALL UL HW-D-0611 (1 AND 2 HOUR) 7 USG SHEETROCK © BRAND FIRECODE CORE GYPSUM PANELS, CUT
Learn More5()(5(1&( &855(17 8/ 6<67(06 ',5(&725< )25 $// *(1(5$/ - 5 6/$%
Learn MoreSTEEL BEAM WITH FIREPROOFING REFERENCE STRUCTURAL DRAWINGS. FOR BEAM SIZE AND FIREPROOFING THICKNESS. USG SHEETROCK © BRAND SHAFT LINER GYPSUM PANELS, CUT TOP
Learn More3 USG Shaft Wall Systems User’s Guide This brochure explains: – What a shaft wall system comprises Design Your System 21 Design Details Good Design Practices Specify Your
Learn MoreUSG STEEL J-RUNNER 1" SHEETROCK BRAND GYPSUM LINER PANEL USG STEEL C-H STUD 1 Shaft Wall-AER-09038 SCALE: DATE: UNITED STATES GYPSUM COMPANY This Shaft Wall Detail must not be used without a complete evaluation by the owner's design professional--to verify the suitability of the design for a given structure.
Learn MoreFire-Rated Assemblies 3 USG Shaft Wall Systems 09 20 00/USG BuyLine 2425 1 Hour Fire-rated Construction Non-loadbearing Acoustical Performance Construction Detail Description Test Number STC Test Number wt. 8 † 5/8 SHEETROCK® brand FIRECODE® Core gypsum UL
Learn MoreUSG Shaft Wall Systems are non-load-bearing gypsum wall partition assemblies constructed from outside the shaft at each floor. Shafts are enclosed early in construction, and the walls are finished later, along with interior partitions. Installation is quick and easy, using components and application procedures familiar to drywall contractors.
Learn Moredetails on page 24. WALLS CEILINGS USG Shaft Wall Systems | 6 COMPONENTS USG Shaft Wall Systems have been comprehensively tested for ire resistan ce ratings only when all of the
Learn MorePartiwall® is a twin stud wall system, which incorporates a single or double layer 25mm Shaftliner™ Mouldstop plasterboard fire barrier within the wall cavity. Shaftliner panels are held in position by lightweight steel H- or I-section studs. Installation of Shaftliner fire barrier is carried out during the framing stage and does not require
Learn More5. For more details and construction methods, refer to UL Design #U415 System A and the USGinstallation instructions. Two-Hour Cavity Shaft Wall (Non-Load Bearing), See Figure 2 1. A minimum 2-1/2-in deep 24 gauge floor and ceiling J-runners, attached to
Learn MoreUSG Shaft & Stair Walls Systems meet the requirements of 1-hour, 2-hour, and 3-hour fire resistive rated assemblies when tested in accordance with ASTM E119 and